Home The buildings Requirements for the installation of magnetic starters with thermal relay

Requirements for the installation of magnetic starters with thermal relay

by 360roomsnews

The starters are designed to start and disconnect the electric motor, as well as a reverse and ensure its full stop. Quite often the equipment fails and requires additional maintenance costs. Its main malfunctions are improper installation, which determines the durability and reliability of the entire installation.

In order for the installation to work properly, and the operation is not so difficult, some recommendations should be taken into account. Installation of the installation must be done on a perfectly even stiff surface (vertical). In addition, the starting element with the relay (thermal) should be installed by observing the norms of the temperature difference.

Quite often it happens that an element with a thermal relay is subjected to blows, shaking and other unfavorable circumstances. These factors can contribute mainly to false operation. Also, to reduce the extraneous influence on the work of the relay (thermal), it is not recommended to place rheostats nearby, which violate the working environment.

An equally important factor during installation is the fact that when connecting to the contact clip, the conductor (one of its ends) should be bent in the P-shaped shape. Otherwise, spring washers are deformed.

Many users do not take into account the coating of the copper ends of the conductor. For the normal operation of the equipment, it is necessary to twist the multi -core conductors before poking, and in the case of working with aluminum conductors, clean them through a file. If necessary, the ends of the conductors are lubricated with cyatim or petroleum jelly. It should also be remembered that the moving parts are strictly not recommended.

After full installation, the magnetic element needs to be inspected and thus verify the serviceability of all its components. After this procedure, it is recommended to check and compare the voltage of the coil with the rated voltage, as well as check the schematic compliance of the correctness of the connection.

For the reliability of electrical locking, it is necessary to check the presence of a solution in closed contacts. This procedure is quite important, as it determines the operational period of operation of the desired equipment. After turning on the starter, you should not be scared of a little noise expressed by a light buzzing. This is considered a normal and permissible phenomenon. Based on this, it must be understood that operational indicators directly depend on the quality of preparatory work and installation.